Compressed Natural Gas Fuel System 47.04 Troubleshooting IMPORTANT: Ensure vehicle is in a well−ventilated area. Close all CNG fuel cylinder shutoff valves. Ensure the engine is off. Close the manual shutoff valve. Remove the fuel panel access cover. Open one fuel cylinder shutoff valve in order to pressurize the system up to the manual shutoff valve (which should remain closed). Perform a leak test on the pressurized components using a gas detector or bubble solution. Hear or smell a natural gas leak Is there a leak or "hissing" sound found on any of the CNG piping components?
Yes No Slowly open the manual shutoff valve and leak test components upstream of the high−pressure solenoid valve Contact Agility Fuel Systems: 1−909−350−7500 or www.agilityfuelsystems.com Yes Is there a leak or "hissing" sound found on any of the CNG piping components? No Start the engine and leak test fuel system components between the solenoid valve and the engine Yes Is there a leak or "hissing" sound found on any of the CNG piping components? Problem is not related to the fuel system Problem solved? No No 05/17/2011 f040813 Fig. 4, Flow Chart: Gas Leak Business Class M2 Workshop Manual, Supplement 20, September 2011 300/4