Aftertreatment System, EPA07 49.01 General Information service literature for all testing, disassembly, cleaning, and repair of the ATD and other com- ponents. procedures is followed, and the driver pushes the regeneration button on the dashboard. The parked regeneration sequence varies accord- ing to engine and vehicle configuration, but it must be exactly followed or regeneration can- not happen. Follow the exact sequence pre- scribed for the vehicle, according to the engine manufacturer’s literature. IMPORTANT: The ATS is part of an integrated engine and emissions management system, controlled by the ECM.
Follow the engine manu- facturer’s procedures, and use the correct equipment when diagnosing or working on any part of the ATS. Regeneration There are two types of regeneration; passive and active. Passive regeneration happens whenever the ATD internal temperature is 572°F (300°C) or higher. This happens during normal loaded vehicle operation, and exhaust gas temperature is no higher than normal. Under load and at highway speeds, passive regen- eration may be all that is necessary to keep the DPF clear. But running light loads, or at low speeds, does not generate enough heat in the ATD for passive re- generation, and soot builds up in the DPF.
As soot builds up in the DPF, it creates back pres- sure and decreases engine efficiency. So at intervals determined by the ECM, which keeps track of mea- surements such as engine hours, fuel consumed, and mileage, the ATS raises the temperature inside the ATD to burn the built-up soot to ash. This re- duces the back pressure and allows the DPF to con- tinue operating efficiently for tens of thousands of miles. During active regeneration, engine rpm rise to fast- idle speed and extra fuel is injected into the ATD to raise its interior temperature very high, over 1112°F (600°C), and turn the trapped soot to harmless ash. There are two types of active regeneration; at-speed and parked.
When conditions permit, the ECM automatically initiates at-speed regeneration. The exact con- ditions for regeneration vary, according to the engine manufacturer’s design. Generally, it can happen only when the vehicle speed is above 7.5 mph, and active regeneration stops when the vehicle slows to 5 mph or below. Parked regeneration is initiated by a driver or technician when the vehicle is safely parked with the exhaust outlet well away from any flammable substance, a specific sequence of Business Class M2 Workshop Manual, Supplement 16, September 2009 050/2