Diesel Exhaust Fluid System, EPA10 49.03 Tank Removal and Installation Daimler Trucks North America vehicles carry diesel exhaust fluid (DEF) tanks in three sizes: 6 gallons, 13 gallons, or 23 gallons. 1 2 3 NOTE: DEF creeps, causing white crystals to form around the line fittings. The presence of crystals does not mean the system has a leak. Replacing fittings or components is not neces- sary unless there is a system failure or a fault code. 6-Gallon Tank Removal IMPORTANT: Discard contaminated DEF or coolant in accordance with EPA regulations. 1. Shut down the engine, apply the parking brake, and chock the tires. 4 2. Open the hood. 10/08/2009 5 f490383 6 3.
Drain the coolant from the cooling system. For instructions, see Group 20 . 1. Vent 2. DEF Level and Temperature Sensor Wiring Harness 3. Coolant Inlet 4. DEF Outlet 5. DEF Inlet 6. Coolant Outlet 4. Place a clean drain pan underneath the tank to catch draining DEF. Uncontaminated DEF may be reused. IMPORTANT: Wait at least five minutes after shutting down the engine to disconnect the DEF lines. Complete purging of the DEF lines re- quires approximately five minutes after the en- gine is shut down. 8. Disconnect the coolant lines from the supply and return ports. Fig. 1, 6-Gallon Tank Ports (Detroit Diesel shown) 9. Disconnect the vent line. 10.
If another chassis-mounted component is located directly aft of the DEF tank, check to see if the component is mounted close enough to prevent the tank from sliding off the mounting studs. If so, remove the nuts, bolts, and washers that se- cure the tank assembly to the frame casting, and remove the assembly from the frame casting. 5. Disconnect the DEF line heater wiring harnesses from the DEF lines at the tank. NOTICE To disconnect a DEF line, push the line coupling in towards the male connector to move the hold- ing clip to the unlocked position, then compress the prongs of the holding clip and pull the line off of the male connector.
Failure to properly re- move a DEF line can result in damage to a line coupling or DEF fitting. 11. Remove the two capscrews that secure the tank and retaining washers on the mounting studs. See Fig. 3 . 12. Remove the two tank retaining washers from the tank mounting studs. 6. Disconnect the DEF lines from the supply and return ports and let the DEF drain into the drain pan. See Fig. 1 or Fig. 2 . 13. Slide the tank off of the mounting studs. Installation 7. Disconnect the wiring harness from the tank header unit. 1. Slide the tank onto the mounting studs. Business Class M2 Workshop Manual, Supplement 17, March 2010 100/1