Electrical System 54.00 Troubleshooting Troubleshooting plates allow the user to monitor and manipu- late the inputs and outputs of the electrical sys- tem. With the multiplexed electrical system, traditional multimeter-based current, voltage and resistance measurements are supplemented, or in some cases replaced, by software tools that can read and control the electronic signals and devices of the system. ServiceLink ® is the tool that is used to troubleshoot the Business Class ® M2 electrical system. The other control module icons, listed below, will have only a General Info screen, a Faults screen, and a Templates screen.

Chassis Module (CHM) The modules of the multiplexed electrical system communicate on both J1939 and J1708/J1587. The primary datalink for the electrical system is J1939, and is used for all control messaging and trouble- shooting. J1708/J1587 is the secondary datalink and is used for limited troubleshooting. Fault codes are displayed on the instrument cluster, and can also be viewed with ServiceLink. The General Info screen displays information about the particular module such as make, model, hard- ware version, and software version. The Faults screen displays the active and historic faults for the particular module on the particular datalink.

The Tem- plates screen gives a directory of Datalink Monitor Templates available for troubleshooting the particular module. These templates allow the user to monitor and manipulate the inputs and outputs of the electri- cal system. Expansion Module (EXM) Since the modules of the electrical system communi- cate on both J1939 and J1708/J1587, ServiceLink shows information for both datalinks. Although each module connected to the multiplexed electrical sys- tem is represented by an icon within ServiceLink, the Bulkhead Module (BHM) icon is the main icon for troubleshooting the system. This is because the Bulkhead Module is the main controller of the multi- plexed system.

The other icons are secondary and contain generic screens. NOTE: For more specific information about the Bulkhead Module see Section 54.12 . For more specific troubleshooting information see Sec- tion 54.12, Subject 300 . The following screens can be accessed under the Bulkhead Module icon: General Info —Displays information about the BHM such as make, model, hardware version, and software version. Faults —Displays the active and historic faults for all of the control modules on the multi- plexed electrical system. Configuration —Displays the pinout for all of the control modules on the multiplexed electri- cal system compared to the host.

Features —Displays the features that are in- stalled in the BHM. From this screen the user can reload all the currently installed features, or make changes to the vehicle by entering new reference parameters. Flashing —Allows the user to update or reflash the software of the BHM. Templates —Gives a directory of Datalink Monitor Templates available for troubleshooting the multiplexed electrical system. These tem- Business Class M2 Workshop Manual, Supplement 10, September 2006 300/1