Wiring 54.01 Wiring Repair Using Phillips STA-DRY ® Solderless Connectors Parts and Tools 2. Crimp the splice connector onto the wires. Use the type of crimp tool that makes a dimple in the connector. The dimple must be at least 3/16 inch wide or there will be too much space inside the connector and the solder will not flow into the wire. This crimp provides the mechanical reten- tion needed. See Fig. 2 . Parts are available through the Parts Distribution Centers (PDCs) in packages of 25 connectors. Use the connectors and adhesive lined shrinkable tubing shown in Table 1 when making a wiring splice. Tools needed for wiring repair using solderless con- nectors include the following.
A dimple-type crimp tool with a minimum 3/16 inch width. See Fig. 1 for an example of a proper crimp tool. A typical manufacturer for this tool is Thomas & Betts. A heat gun rated at 1000°F (538°C). 08/03/2010 f545673 Fig. 2, Properly Crimped Splice 3. Pull test the wires by hand to ensure the crimp is mechanically solid. 4. A crimp tool that is too narrow will leave exces- sive air gaps in the crimp. The connection will not have the required amount of mechanical strength and the solder will not bond the wire to the connector. Figure 3 shows an example of a bad crimp when the wrong tool is used. A 5. Heat the properly crimped splice connector with the heat gun while slowly rotating the wire.
The solder will take longer to flow than it will for the shrinkable insulation to contract. Heat until the solder band has completely melted into the con- nector. If the shrinkable insulation ruptures and a small amount of solder bubbles out, gently shake the splice to remove the solder. See Fig. 4 . 6. When the connector has cooled, center the shrinkable tubing over the splice and heat the tubing until it has completely sealed the splice and a small fillet of adhesive is visible at the ends of the shrink tube. See Fig. 4 . 08/03/2010 f545671 A. Minimum 3/16 inch width. 7. A three-wire tap splice can be made following the same procedure.
Use a connector that is large enough to fit all the strands of the wires. See Fig. 5 for an example of the completed splice. Procedure Fig. 1, Dimple-Type Crimp Tool 1. Dress the wires to be spliced by stripping the insulation to expose 1/4 inch of copper. Slide a 3-inch section of adhesive coated shrink tubing onto one of the wires. Business Class M2 Workshop Manual, Supplement 19, March 2011 100/1