Wiring 54.01 Datalink Repair Parts 5 Twisted-pair datalink wires may be spliced using a mating connector set. See Table 1 for a typical set of datalink connector parts. 4 4 Procedure 3 3 2 2 1. Cut out any damaged section of datalink wire, keeping the lengths of the two wires equal. See Fig. 1 for an example of a damaged section of datalink wire that has been removed and the datalink prepared for repair. 1 1 08/03/2010 1. Terminals 2. Terminal Lock 3. Connector 4. Twisted-Pair Datalink Wires 5. Damaged Section of Datalink Wires f545669 2. Crimp the terminals onto the wires using the proper crimp tool. 3. Pull test the terminals by hand to ensure the crimp is mechanically solid. Fig.
1, Datalink Splice Parts 4. Insert the terminated wires into the connector body and install the terminal lock. The protocol for J1939 is for the yellow wire to be in cavity 1 and the green wire to be in cavity 2. Note that the lock is installed while holding the wires in position. Test the installation. If the wires slipped back during the lock installation, they will pull out of the connector. 5. Make certain the wires are twisted as close to the entry point of the connector as possible. Plug the two connector halves together. See Fig. 2 . 07/30/2010 f545670 Fig.
2, Datalink Connectors Datalink Connector Parts Description Part Number Quantity Connector Body Plug 23-13148-204 1 Terminal Lock 23-13303-015 1 Terminals 23-13210-020 2 Connector Body Receptacle 23-13148-206 1 Terminal Lock 23-13303-013 1 Terminals 23-13210-030 2 Table 1, Datalink Connector Parts Business Class M2 Workshop Manual, Supplement 19, March 2011 120/1