Batteries 54.03 Battery Testing lyzer detects that the batteries are connected it will remind you to disconnect the pack before starting the test. Connecting the Midtronics Tester be firmly connected to the adaptors before test- ing. If the test message CHECK CONNECTION appears, clean the terminals and/or reconnect the clamps. Battery Test 1. Screw an adapter onto the negative-terminal stud and one onto the positive-terminal stud. See Fig. 2 . NOTE: If the analyzer displays a test message after you start the test see "Test Messages" to determine the cause and remedy. 3 1. Use the arrow buttons at the top of the keypad to scroll to menu choices. Select BATTERY TEST. Press ENTER to select.
4 2 2. Enter the number of batteries being tested (1 to 6) and press ENTER to select. 1 3. Select the rating system CCA, SAE, EN, IEC, DIN, or JIS, then press ENTER. 5 4. Select the appropriate rating value ( Table 1 ) then press ENTER. 5. If the analyzer detects that the temperature of the battery may make a difference in the results, it will ask you to select whether the battery tem- perature is above or below 32°F (0°C). It will re- sume the test after you make the selection and press ENTER. 6 f544326 06/23/2003 1. Negative-Terminal Clamp 2. Negative-Terminal Adaptor 3. Negative-Terminal Battery Jumper 4. Positive-Terminal Jumper 5. Positive-Terminal Adaptor 6. Positive-Terminal Clamp 6.
At the end of the test, the Micro740 will display one of the following results from Table 2 and the measured voltage and CCA, if applicable. If the result is REPLACE BATTERY or BAD CELL—REPLACE, the analyzer will prompt you to press ENTER to generate a battery code. Fig. 2, Battery Connection IMPORTANT: For accurate test results, connect the clamps to the lead adaptors or to the lead bases of threaded studs. Lead stud adaptors are included with the Micro740. Do not connect the clamps directly onto the threaded studs or an inaccurate test result may occur. When the prompt BAT.SERIAL # appears enter the battery serial number.
Use the ARROW but- tons to scroll to the correct digit, then press ENTER to select it and move to the next digit. Pressing the BACK button will move the cursor back one space. When finished, press ENTER. 2. Connect the red clamp to the positive-terminal stud adaptor. 7. Turn on the printer and align the analyzer trans- mitter with the printer receiver. Press and hold the MENU button. Select PRINT RESULTS from the option menu by using the arrow buttons and pressing ENTER. It will take about 30 seconds to print all test results, which are displayed simulta- neously on the screen. 3. Connect the black clamp to the negative-terminal stud adaptor. 4.
Rock the clamps back and forth to ensure a se- cure connection. Both sides of the clamp must Business Class M2 Workshop Manual, Supplement 10, September 2006 140/2