Batteries 54.03 Battery Charging Recharge Time Using Shop Charger for a Three-Battery System Voltage State of Charge Charger Maximum Rate 12.6 100% Ready to Use 50 Amps 30 Amps 20 Amps 10 Amps 12.4 75% 1.8 hours 2.7 hours 3.9 hours 7.5 hours 12.2 50% 3.6 hours 5.7 hours 8.1 hours 15.3 hours 12.0 25% 5.4 hours 8.7 hours 12.9 hours 23.1 hours 11.8 0% 7.5 hours 12.0 hours 17.1 hours 32.1 hours Table 3, Recharge Time Using Shop Charger for a Three-Battery System Voltage State of Charge Charger Maximum Rate Recharge Time Using Shop Charger for a Four-Battery System 50 Amps 30 Amps 20 Amps 10 Amps 12.6 100% Ready to Use 12.4 75% 2.4 hours 3.6 hours 5.2 hours 10.0 hours 12.2 50% 4.8 hours 7.6 hours 10.8 hours 20.4 hours 12.0 25% 7.2 hours 11.6 hours 17.2 hours 31.2 hours 11.8 0% 10.0 hours 16.0 hours 22.8 hours 42.8 hours Table 4, Recharge Time Using Shop Charger for a Four-Battery System Batteries below 11.8 volts should be charged at no more than 10 amps for a minimum of 24 hours per battery.
Check after the first hour and ensure that the battery is not getting hot. dicator color is clear or light yellow; this indi- cates low electrolyte level. Replace these batter- ies. If after using the above charging method you receive a charge and retest result from a Midtronics battery tester and the voltage is above 11.8 volts, continue to charge normally. If the battery voltage is below 11.8 volts, condemn the battery. Refer to the following steps to charge a wet cell battery. 1. Clean the battery terminals. NOTE: If the battery is cold, let it warm up. This will allow a normal charging rate.
On optional batteries with built-in hydrometer (charge indicator), the battery is sufficiently charged when the green dot in the hydrometer is visible. Gently shake or tilt the battery at hourly intervals during charging to mix the electrolyte and check to see if the green dot appears. Do not tilt the battery beyond a 45- degree angle. 2. Make sure that the charger is turned off. 3. Connect the charger to the battery following the manufacturer’s instructions. Rock the charger lead clamps to make sure there is a good con- nection. If the green dot does not appear after a 75 ampere- hour charge, continue charging for another 50 to 75 ampere-hours.
If the green dot still does not appear, replace the battery. NOTE: Batteries with built-in hydrometers (charge indicators) cannot be charged if the in- 4. Turn on the charger and slowly increase the charging rate until the recommended ampere value is reached. IMPORTANT: If the battery feels hotter than 125°F (52°C) or if rapid gassing or spewing of electrolyte occurs, lower the charging rate or stop charging the battery and allow it to cool. Business Class M2 Workshop Manual, Supplement 10, September 2006 150/2