Instrumentation Control Unit, ICU3 54.11 Troubleshooting Air Pressure Gauge Diagnosis Test Test Description Test Result Action 3 Connect an accurate pressure gauge to a delivery port on the foot valve. Yes Gauge is OK. No problem found. Make a 90 psi (621 kPa) brake application while observing the application air pressure gauge in the cluster and the test gauge. Check air line to gauge for kinks, pinches, or wire ties that are crushing the air line feed. If OK, replace the air pressure gauge. No Is the air pressure gauge in the cluster within 11 psi (76 kPa) of the test gauge? 4 Connect an accurate pressure gauge to the air suspension. Yes Gauge is OK. No problem found.
Is the air pressure gauge in the cluster within 11 psi (76 kPa) of the test gauge? No Check air line to gauge for kinks, pinches, or wire ties that are crushing the air line feed. If OK, replace the air pressure gauge. 5 Raise the lift axle. Connect an accurate pressure gauge to the application side of the lift axle air system. Lower the axle and adjust the pressure. If the pressure cannot be controlled with the adjustment knob, check the reverse switch and pressure dump valve. Check the pressure adjustment regulator, replace if it is not controlling the pressure. Otherwise, there is no problem. Is the axle pressure on the instrument panel gauge within 11 psi of the test gauge?
Yes No Check air line to gauge for kinks, pinches, or wire ties that are crushing the air line feed. If OK, replace the air pressure gauge. Table 7, Air Pressure Gauge Diagnosis Fuel Level Gauge Diagnosis NOTE: If the fuel level sensor is below the mini- mum resistance (short to ground) or above the maximum (open), the fuel gauge will read empty. Shorting the fuel sensor wires will not drive the gauge to full scale. The fuel level gauge is controlled by the ICU using a variable resistance input from the fuel level sending unit that is located in the fuel tank. The fuel level sending unit resistance varies linearly from 31±2 Ω with a full tank to 247±3 Ω when empty.
If the ICU3 is measuring a resistance greater than 284 Ω between circuit 47 and ground, the EPA10 cluster will set a fault for fuel level circuit open. If the ICU3 is measuring less than 23.5 Ω between circuit 47 and ground, the EPA10 cluster will set a fault for fuel level circuit shorted low. ServiceLink may be used to monitor for these faults on EPA10 J1939 clusters. On all model years of clusters, the gauge will read empty until the measurement from the sen- sor is between 284 Ω and 23.5 Ω . Refer to Table 8 for the fuel level diagnostic procedure. Business Class M2 Workshop Manual, Supplement 21, March 2012 300/5