Instrumentation Control Unit, ICU3 54.11 Troubleshooting Sensor-Driven Gauge Diagnosis Sensor-Driven Gauge Diagnosis Step Test Procedure Test Result Action Does the gauge stay pegged at the full scale or the bottom of scale reading even though the temperature is at some mid-point or is the complaint an inaccurate reading? Note: Turn the ignition to OFF and disconnect the batteries before continuing. Stays Pegged Go to Step 2. 1 Inaccurate Go to Step 3. Disconnect the connector at the sensor and measure the resistance of the sensor. Does the sensor measure open, shorted, or some mid-range resistance for that sensor, using the table in Specifications 400 ? Open or Shorted Replace the sensor.
2 Locate and repair the wiring fault for that sensor. Use the circuit and pin information tables in Specifications 400 to identify the circuits to troubleshoot. Mid-Range Resistance Remove the sensor and place it in a container of water with a thermometer and heat to a temperature where the resistance can be accurately measured with an ohm meter. Use the resistance table in Specifications 400 for the sensor under test to determine if the measured resistance is appropriate for the temperature. Does the resistance value match the table value? Measure the resistance of the wiring between the ICU and the sensor connector. Locate and repair a partially open or short circuit.
3 Yes No Replace the sensor. Table 9, Sensor-Driven Gauge Diagnosis Data-Driven Gauge Diagnosis Step Test Procedure Test Result Action Data-Driven Gauge Diagnosis If the problem is with the DEF level indicator, use the procedure in Table 12 . Connect ServiceLink and open the datalink monitor template for the instrument cluster. Start the engine and let it run until the operating condition should register on the gauge. For example, oil temperature must be above the minimum position on the gauge. Is the display on the computer within 5% of the position of the gauge in the ICU? Use the troubleshooting procedure for the sensor giving incorrect data.
For example, use the engine manufacturer’s troubleshooting procedure for sensors connected to the engine controller. 1 Yes No Replace the ICU. Table 10, Data-Driven Gauge Diagnosis DEF Level Indicator Diagnosis measured at the tank connector. For Detroit Diesel engines, the level sensor signal uses pins 1 and 2. For Cummins engines, the level sensor uses pins 1 and 4. On Detroit Diesel engines, when the DEF tank is empty, the sensor will measure approximately 240 Ω . When full, it will measure approximately 19.8K Ω . On Cummins engines, when the DEF tank The DEF level indicator is integrated into the fuel gauge, and uses J1939 data from the ACM.
The DEF level is measured by a sealed non-contact variable-resistance sensing assembly located in the DEF tank. The DEF level sensor resistance can be Business Class M2 Workshop Manual, Supplement 21, March 2012 300/8