Instrumentation Control Unit, ICU3 54.11 Troubleshooting Fault Code Diagnosis Step Test Procedure Test Result Action If the message is "nO dATA" or "nO J1939", the ICU is unable to communicate with any other device on the vehicle. Troubleshoot the databus for loss of function. If the message is something with a 3-letter code, for example "no ENG" there is a roll call fault. A roll call fault will show SID 254 Fail 07 on J1587 systems and SPN 639 FMI 07 on J1939 vehicles. Use Table 16 for EPA07 and earlier and Table 17 for EPA10 vehicles to identify the device that is not communicating and causing a roll call fault. 3 Is the message "nO dATA" or another message showing nO something?
Yes No Go to Step 4. EPA07 or Earlier Use Table 16 to identify the device broadcasting the fault code. Refer to the troubleshooting subject for that device to determine how to proceed for the fault it is broadcasting. 4 Is the vehicle an EPA07 or earlier, or an EPA10? EPA10 Use Table 17 to identify the device broadcasting the fault code. Refer to the troubleshooting subject for that device to determine how to proceed for the fault it is broadcasting. Table 13, Fault Code Diagnosis EPA07 ICU J1587/J1708 Fault Codes MID 140 (ICU) SID/PID FMI Description Behavior ACTION: Troubleshoot the vehicle charging system.
Test the alternator, and test for voltage drop in the alternator cables and battery cables. If the vehicle is equipped with a remote sense circuit to the alternator, check the fuse for circuit 123E. P168 1 Low System Voltage The vehicle voltage measured by the ICU is less than 10.5 volts. S240 12 EEPROM Memory Fault The ICU has an internal memory fault. The display may show "- - - - - - -", (seven dashes). ACTION: Replace the ICU. S254 12 Internal Electronics Fault The ICU microprocessor or other internal critical electronics has a fault. The display may show "- - - - - - -", (seven dashes). ACTION: Replace the ICU.
Table 14, EPA07 ICU J1587/J1708 Fault Codes MID 140 (ICU) ICU3 J1939 Fault Codes SA 23 (ICU) SPN FMI Conn/Pin Description Behavior 96 5 D1 (+) D2 Fuel Level Circuit Open The resistance between pins D1 and D2 is greater than 298 ohms. The gauge will point to empty. ACTION: Use the troubleshooting procedure in Table 8 beginning at Step 4. 96 6 D1 (+) D2 Fuel Level Circuit Short The resistance between pins D1 and D2 is less than 23.5 ohms. The gauge will point to empty. ACTION: Disconnect the fuel level sensor connector at the sending unit. Turn the ignition to ON and check the fault code display.
If the fault code for fuel level circuit short (FMI 6) is still active, locate and repair the short in circuit 47 between the LBCU and the fuel level sender. Otherwise use the troubleshooting procedure in Table 8 beginning at Step 5. Business Class M2 Workshop Manual, Supplement 21, March 2012 300/11