Instrumentation Control Unit, ICU3 54.11 Troubleshooting EPA10 Displayed Fault Messages Message System With Active Fault Message System With Active Fault EnG 0 Engine Controller CPC EEC 61 Aftertreatment Control Module (ACM) EnG 1 Engine Controller MCM CEL 74 Cellular Phone tCU 3 Transmission Control Unit SAt 75 Satellite Communications tSU 5 Transmission Shift Unit rAd 76 Radio CdU 42 Collision Detection Unit SYS ### Where ### is the source address of any other J1939 controller that is not in this list.

AbS 11 Antilock Brake Controller SbU 83 Seat Belt Unit Space Table 17, EPA10 Displayed Fault Messages Gauge Backlighting Diagnosis Gauge Backlighting Diagnosis Test Test Description Test Result Action 1 Is only the air pressure gauge module backlighting affected? Yes Go to Test 2. 2 Remove the three air gauge module screws and carefully lift the air gauge module off the back of the ICU while leaving the ribbon cable connected. Yes Replace the air pressure gauge module. No Go to Test 3. Inspect the ribbon cable connection to the ICU PC board. Make sure that it is plugged in all the way. Repair the ribbon cable connection as necessary. Is the ribbon cable connection OK?

No 3 Turn the headlights on and press the dimmer switch to increase then decrease the backlighting. Yes Use the troubleshooting procedures in Section 54.30 . Is the backlighting inoperative for all of the HVAC, headlight switch, and ICU? ICU only Go to Test 4. 4 Access the back of the ICU and disconnect the two electrical connectors. Replace the ICU. Turn the headlights on. Yes Measure voltage between pins A1(+) and D3(–) while increasing and decreasing the dimmer switch. Go to Test 4. The voltage should range between approximately 2.5V (dim) and 11.3V (full bright). No Does the measured voltage change through this range? Business Class M2 Workshop Manual, Supplement 21, March 2012 300/13