Freightliner — Freightliner Business Class M2 Workshop Manual

Instrumentation Control Unit, ICU3 54.11 Troubleshooting ICU Warning and Indicator Lamps Lamp Symbol Bulb Check Activation Control Pin Buzzer Operation Low Oil Pressure YES Lamp is ON when commanded by the engine controller. The lamp will latch on for a minimum of 30 seconds. Data Buzzer is active when the lamp is ON High Coolant Temperature YES Lamp is ON when commanded by the engine controller. The lamp will latch on for a minimum of 30 seconds. Data Buzzer is active when the lamp is ON Lamp is ON when ground is applied to the control pin or Lamp is ON/ FLASHING when commanded by the transmission controller or the retarder.

High Transmission Temperature YES A4 and Data None Option 1 (Air Filter Restriction) AIR FILTER NO Lamp is ON when ground is applied to the control pin or Lamp is ON when commanded by the BHM SA 33, SPN 5086. C14 and Data None Option 2 (Washer Fluid Low) WASH FLUID NO Lamp is ON when ground is applied to the control pin or Lamp is ON when commanded by the BHM SA 33, SPN 80. A6 and Data None INTAKE HEATER Option 3 (EPA07 and earlier - Intake Heater EPA10 - Wait to Start) Lamp is ON when ground is applied to the control pin or Lamp is ON when commanded by the engine controller SA 0, SPN 1081.

A7 and Data None WAIT NO TO START Option 4 (EPA07 and Earlier - Water In Fuel) WATER IN FUEL NO Lamp is ON when ground is applied to the control pin or Lamp is ON when commanded by the BHM SA 33 SPN 5086. A8 and Data None Option 5 (Wheel Spin) WHEEL SPIN NO Lamp is ON when ground is applied to the control pin or Lamp is ON when commanded by the BHM SA 33. B1 and Data None Lamp is ON when ground is applied to the control pin or Lamp is ON when commanded by the engine controller SA 0.

Option 6 (Low Water) LOW WATER NO B8 and Data None Lamp is ON when ground is applied to the control pin or Lamp is ON when commanded by the transmission controller Option 7 (Check Transmission) CHECK TRANS YES C11 and Data None Option 8 (Idle Management) MGMT NO Lamp is ON when ground is applied to the control pin. C1 and Data None IDLE Business Class M2 Workshop Manual, Supplement 21, March 2012 300/17