Freightliner — Freightliner Business Class M2 Workshop Manual

Bulkhead Module 54.12 Troubleshooting A/C Clutch Function Fault Conditions Description of Fault Action Taken by BHM A/C clutch wiring is shorted. BHM may transmit a J1939 and/or a J1708 fault message. Table 2, A/C Clutch Function Fault Conditions Alternator Charging Function Input/Output Conditions Input to BHM from Alternator "I" Terminal Output from BHM via J1939 Message to ICU Output from ICU 14 volts Charge status of J1939 message is high. NO CHARGE light is off. 0 volts Charge status of J1939 message is low. NO CHARGE light is on.

Table 3, Alternator Charging Function Input/Output Conditions Backup Function Transmission Type Input to BHM BHM Conclusion Manual transmission Backup switch is closed. Transmission is in reverse. J1939 message from transmission indicates either: Automatic transmissions Current Gear = Reverse Transmission is in reverse.

Selected Gear = Reverse Gear Range = R Table 4, Backup Function Backup Function Input/Output Conditions Backup Function Input/Output Conditions Ignition Switch Transmission Status Backup Lights/Alarm * Inputs to BHM Output from BHM Ignition Switch Transmission Status Backup Lights/Alarm * Inputs to BHM Output from BHM On/Acc Reverse On On/Acc Not Reverse Off * Via J1939 message to the CHM Table 5, Backup Function Input/Output Conditions Off Not Reverse Off Off Reverse Off Description of Fault Action Taken by BHM Backup Function Fault Conditions Ignition switch status is in error.

BHM will assume the ignition switch is in the on position and may transmit a fault message on the J1939 and/or J1708 datalinks. Backup lights/alarm wiring shorted. BHM may transmit a J1939 and/or a J1708 fault message. Table 6, Backup Function Fault Conditions Business Class M2 Workshop Manual, Supplement 22, September 2012 300/11