Freightliner — Freightliner Business Class M2 Workshop Manual

Smart Switches 54.14 Troubleshooting Typical Smart Switch Faults 1. Log on to ServiceLink ® and click on the BHM icon. Smart switch faults must be diagnosed to determine if the smart switch itself is the cause of the problem. See Table 1 for symptoms that might indicate a smart switch fault. 2. Click on the Features tab. 3. All of the reference parameters programmed into the Bulkhead Module (BHM) that use a smart switch have "(Smart Switch)" in the description of the reference parameter. See Fig. 1 . See Table 2 for descriptions of smart switch faults.

Determining Which Smart Switches the Vehicle is Programmed to Use Use the following instructions to determine which ve- hicle functions use a smart switch.

Smart Switch Faults J1587 Fault J1939 Fault Fault Description MID SID FMI SA SPN FMI 164 022 07 33 6918 07 Missing Smart Switch 164 021 07 33 6919 07 Duplicate Smart Switch 164 020 07 33 6920 07 Extra Smart Switch 128 6914 04 Smart Switch VBAT Short to Ground 129 6914 04 Smart Switch VBAT Short to Ground 130 6914 04 Smart Switch VBAT Short to Ground 131 6914 04 Smart Switch VBAT Short to Ground Table 1, Smart Switch Faults Definition of Smart Switch Faults Problem Description Missing Smart Switch Fault The BHM cannot detect a smart switch for a function that is programmed into the BHM by a reference parameter For example, no fog lamp switch, but a reference parameter for fog lamps is programmed into the BHM.

Duplicate Smart Switch Fault The BHM has detected more than one smart switch for a particular function programmed into the BHM by a reference parameter. For example, two fog lamp smart switches are connected. Extra Smart Switch Fault The BHM detects a smart switch for a function that is not programmed into the BHM by a reference parameter. For example, a fog lamp switch is connected, but the vehicle is not programmed for fog lamps. Smart Switch VBAT Short to Ground The smart switch indicator and/or backlight drive circuit is overloaded. Only smart switches connected to a SEM report this fault.

Table 2, Definition of Smart Switch Faults Business Class M2 Workshop Manual, Supplement 22, September 2012 300/1