Freightliner — Freightliner Business Class M2 Workshop Manual

Forward Lighting Systems 54.27 Troubleshooting Fault Conditions If the BHM is programmed to transmit fault codes, they can be viewed through ServiceLink. Fault mes- sages may be transmitted on the J1939 and/or the J1708 data links until the ignition switch is turned off. See Table 9 for the turn signal lights fault conditions and the resulting actions of the BHM. The reference parameters that program the BHM determine whether or not a fault code is broadcast. Therefore, even if the BHM detects a fault, a fault code may not be transmitted.

ICU Turn Signal Lights Input/Output Conditions Multifunction Turn Signal Switch Position J1939 Right Turn Message J1939 Left Turn Message Input to ICU Outputs from ICU Right Turn On Off Left Turn Off On Off Off Off Table 7, ICU Turn Signal Lights Input/Output Conditions Turn Signal Lights System Input/Output Conditions Inputs to BHM Outputs from BHM J1939 Left Turn Message J1939 Right Turn Message Hazard Switch Position Left Turn and Stop Lights Right Turn and Stop Lights Off On Off Activated Deactivated On Off Off Deactivated Activated Off Off On Activated Activated Table 8, Turn Signal Lights System Input/Output Conditions Turn Signal Lights Fault Conditions Left turn switch position is unavailable or in error.

BHM will assume the J1939 left turn switch position is off. Description of Fault Action Taken by BHM Right turn switch position is unavailable or in error. BHM will assume the J1939 right turn switch position is off. Hazard switch position is unavailable or in error. BHM will assume the hazard switch is on. ICU sends an error indicator in the J1939 left turn switch position message. BHM may transmit a J1939 and/or a J1708 fault message. ICU sends an error indicator in the J1939 right turn switch position message. BHM may transmit a J1939 and/or a J1708 fault message. BHM fails to receive five consecutive left turn switch messages from the ICU.

BHM may transmit a J1939 and/or a J1708 fault message. BHM fails to receive five consecutive right turn switch messages from the ICU. BHM may transmit a J1939 and/or a J1708 fault message. Left turn signal lights wiring shorted. BHM may transmit a J1939 and/or a J1708 fault message. Business Class M2 Workshop Manual, Supplement 10, September 2006 300/4