Freightliner — Freightliner Business Class M2 Workshop Manual

Forward Lighting Systems 54.27 Troubleshooting Marker Lights Fault Conditions Description of Fault Action Taken by BHM Status or position of the headlight switch is in error. BHM assumes the headlight switch is on, and may transmit a fault message on the J1939 and/or J1708 data links. Status or position of the marker interrupt switch is unavailable or in error. BHM assumes that the marker interrupt switch is off, and may transmit a fault message on the J1939 and/or J1708 data links. Any marker light output wiring is shorted. BHM may transmit a J1939 and/or a J1708 fault message.

Table 14, Marker Lights Fault Conditions Fog Lights Function Input and Output Conditions See Table 15 for the Bulkhead Module (BHM) re- sponses to the fog lights input/output conditions.

Fog Lights Input/Output Conditions Inputs to BHM Outputs Ignition Switch Position J1939 High Beam Status from ICU Fog Light Switch J1939 message from BHM to CHM Fog Lights Off Off On Deactivate Off On On On Deactivate Off On Off On Activate On Table 15, Fog Lights Input/Output Conditions Snowplow Lights Provision Effect of the Snowplow Lights Provision on Forward Lighting System Troubleshooting Input and Output Conditions See Table 16 for the Bulkhead (BHM) responses to the snowplow light input/output conditions. Fault Conditions Identification of faults in the forward lighting system can proceed normally when the snowplow lights pro- vision is installed and operating correctly.

However, problems with the snowplow light control modules and incorrect connections to the snowplow light har- ness cannot be identified through the J1939 or J1708 datalinks. See Table 17 for the snowplow lights fault conditions and the resulting actions of the BHM. The reference parameters that program the BHM determine whether or not a fault code is broadcast. Therefore, even if the BHM detects a fault, a fault code may not be transmitted. A bad snowplow light control module or improper connections can result in one or more lamps not illu- minating when directed by the BHM, or in having one or more lamps driven by the incorrect signal.

Other indications specifically associated with incorrect con- nections of the M2 106V snowplow light harness in- clude relay chatter in one of the snowplow light con- trol modules or a fault message indicating the park light and/or low-beam output is shorted. If the BHM is programmed to transmit fault codes, they can be viewed through ServiceLink. Fault mes- sages may be transmitted on the J1939 and/or the J1708 datalinks until the ignition switch is turned off. Business Class M2 Workshop Manual, Supplement 10, September 2006 300/7