Trailer Electrical Systems 54.29 General Information Installation or Replacement Guidelines When installing or replacing any part of the electrical trailering system, follow these guidelines: Make ground connections at factory-provided ground stud locations whenever possible. If there is not a ground stud available, it will be necessary to add a bolt or self-threading fas- tener to connect the ground lugs to the frame rail. Route all wiring so that it will not be exposed to harmful conditions such as, moving parts, excessive heat, chafing, or saturation with oil or grease. Secure and protect all electrical components.

Use appropriate mounting and installation tech- niques such as, retaining clips, harness protec- tion, and correct hardware. Be sure to clean all paint, dielectric enamel, and road grime from the ground stud or frame before connecting the new ground leads. After the connections are secured, use a dielectric enamel on the ground connections to protect against corrosion. Removal of electrical components for an ex- tended period of operation requires proper weatherproofing to avoid system damage and electrical faults. Business Class M2 Workshop Manual, Supplement 10, September 2006 050/2