Freightliner — Freightliner Business Class M2 Workshop Manual

Interior Lighting Systems 54.30 General Information Current Capacity in the BHM shutdown of that output. If adding addi- tional interior lights to a vehicle, do not exceed the current capacity of control module output. See Table 1 for identification of possible courtesy light outputs and the current capacity of those outputs.

For cab configurations where the BHM powers many courtesy lights, it is necessary to be aware that ex- ceeding the current capacity of a BHM output results Courtesy Light Outputs Module Pin Connector Function Current Capacity BHM A B5 Dome lights battery power 6.7A * BHM B B5 Dome lights and optional door courtesy lights switched power 6.7A CHM C C3 Door courtesy lights (unused fog light output) 6.7A * Pins B5-A and B7-A12 (smart switch battery power) are fed from the same BHM circuit board trace. The maximum combined current capacity for both pins is 6.7A. Pins C3-C and C3-D (optional fog light) are fed from the same CHM circuit board trace.

The maximum combined current capacity for both pins is 6.7A. Table 1, Courtesy Light Outputs Business Class M2 Workshop Manual, Supplement 10, September 2006 050/3