Freightliner — Freightliner Business Class M2 Workshop Manual

Electronic Stability Control 54.31 Front Solenoid Valve Removal and Installation Removal 1. Shut down the engine and chock the tires. 2. Release the pressure from the air reservoirs. 3. Disconnect the electrical connector from the front solenoid valve. 3.1 Turn the collar on the connector counter- clockwise until it stops. 4. Disconnect the air lines. 3.2 Disconnect the connector. 5. Remove the two mounting screws and nuts. 6. Remove the front solenoid valve. Installation 1. Mount the new solenoid valve and install the two screws and nuts. Tighten the nuts to 8 lbf·ft (11 N·m). 2. Connect the air lines to the front solenoid valve. 3.

Connect the electrical connector to the front sole- noid valve. Hand-tighten only. 4. Verify the operation of the solenoid valve. 4.1 Start the vehicle and allow the air reser- voirs to fully charge. 4.2 Shut down the engine. 4.3 Apply the brakes and check for air leaks at the front solenoid valve. 4.4 Turn the ignition to ON. Verify that the ATC/RSC/ESC indicator lamp operates correctly. 4.5 Activate the front solenoid valve using the Meritor WABCO PC Diagnostics tool, TOOLBOX. 4.6 Check for air leaks at the front solenoid valve. If valve leaks, make necessary re- pairs. 4.7 If front solenoid valve fails to cycle, turn off the ignition and make sure the electri- cal connections are tight.

Then, turn the ignition switch on and check the valve again. If the front solenoid valve still fails to cycle, check for fault codes. Business Class M2 Workshop Manual, Supplement 19, March 2011 120/1