PTO and Pump Electrical Controls 54.38 Troubleshooting Fire Pump Controls Function Electrical Diagnosis Test No. Test Procedure Test Result Action 3 Make sure the vehicle has full air pressure. Turn the ignition on. Yes Go to test no. 4. Using the appropriate solenoids Datalink Monitor template, attempt to engage the fire pump using the smart switch in the dash while observing the status of the pressure switch under the "Inputs to BHM" heading for the two solenoids that control the fire pump. See Fig. 2 and Fig. 3. For the solenoid that does not change pressure switch status: Check solenoid pressure switch feedback circuit. NOTE:
Under normal operation with the switch off, one solenoid should indicate air pressure, the other one should not. When the switch is turned on and the pump engages, the solenoid that indicated pressure should now be off, and the one that was off should now indicate pressure. Check the solenoid pressure switch. See Section 42.19. No Check the air lines. Does the status of the pressure switch change for both solenoids when the switch is turned on, even if it reverts back to its initial state? If the above items are OK, replace CHM. 4 In ServiceLink, open the "Fire Pump Interlocks" Datalink Moni- tor template. Yes Determine the cause for interlock drop out and repair as necessary.
Using Table 5 , determine which fire pump interlocks are used based on the reference parameter programmed into the BHM. Check both fire pump solenoid out- put circuits for amperage. If either exceeds 0.85A, make necessary repair or modification. Engage the fire pump using the switch in the dash. No Do any of the necessary interlocks drop out when the fire pump solenoids drop out? If amperage is OK, check for me- chanical problem. Business Class M2 Workshop Manual, Supplement 22, September 2012 300/4