PTO and Pump Electrical Controls 54.38 Troubleshooting PTO and Fire Pump Control J1939 Fault Codes SA SPN FMI Description Action 33 6954 07 End of Frame (PTO and fire pump control)–no air pressure feedback Solenoid is not activated, but CHM senses that the pressure switch is in an unexpected state. For example, a normally closed solenoid is off, but air pressure is detected. Check the following: Air system Pressure feedback circuit including the ground. Solenoid–pressure switch may be stuck.
6955 07 End of Frame (PTO and fire pump control)–unexpected air pressure feed- back Chassis Module engages solenoid, but the pressure switch does not change status indicating that the so- lenoid supplied, or exhausted, air downstream. Check the following: Air system Pressure feedback circuit including the ground. Solenoid–pressure switch may be stuck. Table 7, PTO and Fire Pump Control J1939 Fault Codes Business Class M2 Workshop Manual, Supplement 22, September 2012 300/9