Freightliner — Freightliner Business Class M2 Workshop Manual

PTO and Pump Electrical Controls 54.38 Troubleshooting You must enter Test Mode before using the test buttons to operate the outputs. Please exit Test Mode when finished. Enter Test Mode Test Mode Double click to display fault codes, Double click again to exit. Mode Exit Test ON Inputs to BHM: Outputs from BHM: (From CHM to BHM) (From BHM to CHM) (pin) Press. Switch (pin) Sol. Output (pin) Sol.

Output Solenoid Output Test Status AMU SOLENOID 0 C5.A C5.H Status Status C5.H ON AIR ON OFF OFF OFF Status AMU SOLENOID 1 C5.B C5.J Status Status ON C5.J AIR ON OFF OFF OFF Status AMU SOLENOID 2 C5.F C5.L Status Status ON C5.L AIR ON OFF OFF OFF Status AMU SOLENOID 3 C5.G C5.M Status Status ON C5.M AIR ON OFF OFF OFF This template monitors and tests the Air Manifold Unit solenoid valves. Use Servicelink to determine which AMU bank and pins correspond to the function you wish to test (e.g. suspension dump on AMU2 output pin C5.L).

When the function is activated by a smart switch on the dash and all necessary conditions are met, the BHM will send a command to the CHM to activate the corresponding AMU solenoid valve. The CHM will then respond back indicating that the solenoid output has been activated. The CHM also sends the BHM the status of the pressure switch (note: system must be charged with air when performing AMU solenoid tests). In Test Mode the solenoids can be tested using the buttons on this template, thus bypassing the smart switches in the dash. Note: Smart switches are tested in a separate template. Note: Pressure switch status will be "Air On" when the output is ON for N.C.

solenoids, and "Air Off" when the output is ON for N.O. solenoids. 01/05/2006 f544753 Fig. 2, AMU Solenoids Template, Pressure Switch Status Business Class M2 Workshop Manual, Supplement 22, September 2012 300/11 FAULTS