Optional Power Switches and Connection 54.39 Troubleshooting Troubleshooting For electrical troubleshooting, see Table 1 . Description of Fault Possible Cause Electrical Troubleshooting No power at an optional switch output. Switch is on. Check appropriate power distribution module (PDM) fuse to see if it is open or missing. F25 supplies switches 1 and 2. F26 supplies switches 3 and 4. No power at an optional switch output. Switch is on and power supply fuse is proven good. Check the identification label on the output circuit. Make sure the output circuit is identified as belonging to the optional switch in use. Intermittent or no operation. Loss of connection.
Could be caused by loose electrical connection(s), disengaged terminal connection(s), or damaged wire(s). Trace the suspect circuit. Table 1, Electrical Troubleshooting Business Class M2 Workshop Manual, Supplement 10, September 2006 300/1