All-Wheel-Drive Electrical Controls 54.41 General Information two switch contacts of the parking brake pressure switch function independently from one another and are activated at different parking brake pressures. See Table 1 for the circuit function of the parking brake pressure switches in the AMU/AAVA. high-range position on the transfer case range switch sends power through the closed contacts of the high- range relay to the high-range solenoid and the high- range interlock relay. The powered high-range sole- noid sends compressed air to the transfer case housing shifting the transfer case into high range. See Fig. 4 .
As parking brake pressure increases to 2 to 5 psi (14 to 34 kPa), the normally open switch 2 closes and connects circuits GND and 493T. With switch 2 closed, all the coils of the transfer case interlock re- lays are provided a ground, meaning the relays are energized. According to the selected position of the transfer case range switch, power is supplied from the range switch through the corresponding transfer case and transfer case interlock relays to the appro- priate range solenoid. The interlock relays ensure that when there is active pressure in the parking brake pneumatic circuit, the transfer case cannot be shifted out of the selected range.
When the parking brake is released, the pressure of the parking brake pneumatic circuit will rise. As park- ing brake pressure reaches 2 to 5 psi (14 to 34 kPa), the normally open switch 2 closes and energizes the transfer case high-range interlock relay. Now the high-range solenoid is receiving power from both the high-range relay and the high-range interlock relay. The high-range interlock relay prevents the transfer case from being shifted out of high-range while there is active pressure in the parking brake pneumatic circuit. As parking brake pressure reaches 70 to 84 psi (483 to 579 kPa), the normally closed switch 1 opens and deactivates the transfer case relays.
Above these pressures, power is still supplied to the selected AWD solenoid via the activated interlock relay. No transfer case range shifts are allowed until the inter- lock relays are deactivated. Deactivation of the inter- lock relays occurs only when the parking brake is applied and the pressure at the parking brake switch returns to 0 psi. Transfer Case High Range As parking brake pressure increases to 70 to 84 psi (483 to 579 kPa), the normally closed switch 1 opens and deactivates the transfer case high-range relay. At this pressure, the high-range solenoid is powered only by the high-range interlock relay.
The transfer case will remain locked in high range until the park- ing brake is applied and the pressure at the parking brake switch returns to 0 psi. Applying the parking brake decreases the pressure of the parking brake pneumatic circuit. As pressure falls to 70 to 84 psi (483 to 579 kPa), the high-range relay is energized. The high-range solenoid is now receiving power from both the high-range relay and the high-range interlock relay. When the pressure decreases to 2 to 5 psi (14 to 34 kPa), switch 2 will open and de-energize the high-range interlock relay.
With the parking brake applied and 0 psi at the park- ing brake pressure switch, the normally closed switch 1 of the parking brake pressure switch energizes the high-range relay in the auxiliary PDM. Selecting the Parking Brake Pressure Switch Circuit Function Pin Circuit Switch Connection Function A 493R Switch 1 (normally closed) Switch 1 is closed from 0 psi through approximately 70 to 84 psi (483 to 579 kPa). When closed, switch 1 connects circuits 493R and 493P. This activates all the coils of the transfer case range relays. Above 70 to 84 psi (483 to 579 kPa), switch 1 opens and the transfer case range relays are deactivated.
B 493P Switch 1 (normally closed) C GND Switch 2 (normally open) Switch 2 is open from 0 psi through approximately 2 to 5 psi (14 to 34 kPa). When open, switch 2 deactivates all the coils of the transfer case range interlock relays. Above 2 to 5 psi (14 to 34 kPa), switch 2 closes and connects circuits GND and 493T. This activates the transfer case range interlock relays and locks the transfer case into the selected range. D 493T Switch 2 (normally open) Table 1, Parking Brake Pressure Switch Circuit Function Business Class M2 Workshop Manual, Supplement 22, September 2012 050/4