Cab Air Suspension 60.14 Quick-Connect Fittings Fitting Leakage Repair 1. With the vehicle parked on a level surface, apply the parking brakes and chock the tires. 2 1 3 4 5 6 WARNING Do not disconnect any air lines in the cab sus- pension system without first blocking the cab securely. If the cab isn’t securely blocked, dis- connecting an air line could cause the cab to fall abruptly, possibly resulting in serious injury. 2. Place blocks between the frame and the bottom of the cab to keep the cab in position when the air spring is deflated. 03/09/99 f310792 3. Drain all air from the air tanks. 1. Fitting Body 2. Shoulder 3. Release Ring 4. Clamping Ring 5. Collar 6.
Nylon Tube WARNING Air lines under pressure can whip dangerously if disconnected under pressure. Drain all air from the air tanks before disconnecting air lines. Dis- connecting pressurized air lines can cause per- sonal injury and/or property damage. Fig. 1, Parts of the Quick-Connect Fitting A B 4. Remove the nut and washer that attach the verti- cal linkage to the horizontal control lever. Discon- nect the vertical linkage from the control lever. C 5. Rotate and hold the control lever up until all air is exhausted from the air spring. 6. Push the collar of the quick-connect fitting into the fitting body with a 1/4-inch (7-mm) open-end wrench; see Fig. 1 .
With the collar pushed into the fitting, pull the tubing from the fitting. The fit- ting should easily release the tubing. NOTE: Find the mark on the tubing, about 1/4 inch (7 mm) from the end, where the collar clamped the tubing; see Fig. 2 . If this mark is less than 1/4 inch (7 mm) from the end of the tubing, the fitting was not assembled correctly and could have caused an air leak. 03/09/99 f310793 A. Square end of the tube against the shoulder. B. The collar clamps the tube here. C. Push the collar to release the tube. Fig. 2, Correctly Installed Quick-Connect Fitting seal correctly; cut the end of the tubing at an angle of 90 degrees. 7.
Inspect the end of the tubing for paint or debris that could prevent full insertion of the tubing into the fitting. Remove any dirt from the tubing and fitting. 9. Insert the squared-end of the tubing into the fit- ting. An initial resistance is felt when the tubing touches the clamping ring section of the collar. Push the tubing past this resistance another 1/4 inch (7 mm) or so until the tubing is fully against the shoulder. 8. Check that the end of the tubing is cut square. If the tubing is cut at an angle, the fitting will not Business Class M2 Workshop Manual, Supplement 14, September 2008 100/1