Freightliner — Freightliner Business Class M2 Workshop Manual

Cab Heater and Air Conditioner, Valeo 83.00 Troubleshooting Problem Blower Not Working Problem Blower Not Working Problem with the wiring. Refer to "Blower Motor Circuit Tests" for diagnosis. Possible Cause Remedy The control head is not working. A fuse is blown. The blower motor is not working. Component and System Tests here. The valve is very sensitive to contamination. The contaminant is usually water. Less than a drop of water is all it takes to make the valve stop work- ing. When water reaches the valve, the extreme cold that results from the pressure drop freezes the water, forming a block of ice in the valve.

After the system shuts down and the valve warms, the ice melts and the valve operates again, only to be blocked again when the moisture returns and freezes. Use the following component and system tests to diagnose an HVAC problem. Receiver-Drier To the touch, the entire length of the receiver-drier should be the same temperature. If the receiver-drier is not the same temperature, it may indicate a block- age or low charge. Any blockage can cause high head pressures. Cooling System On-and-off operation of the expansion valve means that the receiver-drier is not removing moisture from the system.

Refrigerant Compressor Although they are not physically connected, there is a close tie between the air conditioner and the cool- ing system. Poor air conditioner cooling can be the result of a problem in the cooling system. Compressor problems usually show in one of four ways: abnormal noise If the cooling system does not work correctly, the heat of the engine will rise to abnormal levels. The added heat will transfer to the air conditioner, other underhood parts, and maybe make its way into the cab. The added heat makes it necessary for the air conditioner to work harder and reduces the ability of the air conditioner to cool the air in the cab.

seizure leakage low suction and discharge pressures Resonant compressor noises are not causes for alarm. Irregular noise or rattles are likely to be caused by broken parts. To check for seizure, de- energize the magnetic clutch and see if the drive plate can be turned. If it won’t turn, the compressor has seized. See Group 20 for cooling system troubleshooting, and see the engine manufacturer’s service manual for other details about cooling system problems. Expansion Valve Low discharge pressure may be caused by not enough refrigerant, not enough belt tension, or a blockage somewhere in the system. These things should be checked before servicing the compressor.

Evaporator Problems with the expansion valve may be caused by the valve being stuck closed or open. When the valve is stuck closed, the evaporator coil and the ex- pansion valve will be at outside temperature. When the valve is stuck open, both the coil and the valve will be extremely cold with frost or ice buildup. The evaporator coils are basically trouble-free when airflow over the fins is not blocked. The filter next to the evaporator removes debris. If the filter is in- stalled, no blockage can occur. Because the expansion valve channels are very small, blockages in the system tend to be found Business Class M2 Workshop Manual, Supplement 13, March 2008 300/7