Cab Heater and Air Conditioner, Valeo 83.00 Troubleshooting sumes full recirculation mode for 20 minutes. This cycle repeats as long as the system re- mains in recirculation mode. The target position corresponds to an end stop and an additional 1 second extra drive in the same direction (to guarantee sealing) has been performed. The control head senses the recirculation door posi- tion by reading the feedback voltage from the actua- tor position sensor. The feedback voltage will be less than the 5V reference voltage sent by the control head to the sensor.
The recirculation door should move from one ex- treme position to the other when the recirculation button is pressed on and then pressed off. Perform the tests in Table 5 in the sequence pre- sented. The directions under the column "What to Do if Test Fails" are sometimes dependent on good re- sults from previous tests. If any of the tests fail, stop and perform the specified repair or check. If the recir- culation door actuator passes the tests in Table 5 and the actuator still does not operate properly, check for mechanical problems with the actuator.
To quickly check for normal operation, set the fan switch to high and listen for a change in the sound of the blower near the HVAC unit while pressing the recir- culation button on and off. The blower will be louder when recirculation is enabled. The target position is based on the recirculation but- ton setting and internal control head algorithms. The desired position is considered reached when one of the following conditions is true, although this does not necessarily mean that the position actually corre- sponds to the desired recirculation button setting (for example, if the actuator movement is limited due to an obstruction). The actuator feedback position has been reached.
The actuator is stalled for more than 1 second; the actuator feedback position does not change for more than 1 second. Recirculation Door Actuator Circuit Tests Test Conditions Test Point Good Result What to Do if Test Fails actuator motor drive circuit key on, engine off Measure across pins 5 and 6 of the recirculation door actuator connector. 9V+ for about 1 second * Check wiring between control head and recirculation door actuator. recirculation door actuator connector removed fan (blower) speed on low If wiring is okay, replace the control head.
change the recirculation setting while observing the digital multimeter (DMM) actuator position sensor reference voltage circuit key on, engine off Measure between pin 10 of the recirculation door actuator connector and the battery negative post. 5V recirculation door actuator connector removed actuator position sensor reference ground circuit key on, engine off Measure between pin 8 of the recirculation door actuator connector and the battery positive post. 12V * recirculation door actuator connector removed Business Class M2 Workshop Manual, Supplement 13, March 2008 300/11