Refrigerant Compressor, Denso 83.03 Compressor Oil WARNING center, it is the only acceptable oil to use in a system with a Denso compressor. Before doing any of the work below, read the in- formation under Safety Precautions 100 . Failure to read the safety precautions and to be aware of the dangers involved when working with refriger- ant, could lead to serious personal injury. Denso Total System Oil Volume Denso refrigerant compressors are supplied with ap- proximately 4.5 oz. of ND-8 oil, but the vehicle con- figuration affects the total charge volume.
If a com- plete new oil charge is required, the amount will be determined by the volume stated in the new com- pressor literature, and the volume listed in PartsPro. The two amounts will be combined to give the total oil charge required. If a complete new oil charge is not required, use the oil balancing info in Sec- tion 83.00, Subject 220 . General Information Denso compressors require ND-8 PAG refrigerant oil.
When the air conditioning system is operating, refrig- erant oil can leave the compressor and circulate through the system with the refrigerant, but the refrig- erant oil cannot leave the system except when there is a leak, when the refrigerant is recovered, or when a system part is replaced. It is important that the air conditioning system has the correct amount of refrigerant oil for proper opera- tion. Too little oil will result in compressor failure. Too much oil will degrade the performance of the air con- ditioner, and cause damage to the compressor. IMPORTANT:
Whenever the air conditioning system is discharged or recovered, the recov- ered oil, from the charging machine, must be measured in order to know how much oil must be returned to the system. When a system com- ponent is replaced, a quantity of new oil equal to the recovered oil plus the oil coating the in- side of the component must be returned to the system. New oil must be from a container that has not been opened or that has been tightly sealed since its last use. Tubing, funnels, or other equipment used to transfer the oil must be very clean and dry. When handling refrigerant oil:
Be sure that the oil is free of water, dust, metal powder, and other foreign sub- stances; Do not mix the refrigerant oil with other types or viscosities of oil; Quickly seal the oil container after use. Refrigerant oil absorbs moisture when ex- posed to the air for any period of time. Order Denso PAG oil (ND-8OIL, P/N DII LA446963 0040) from your local Freightliner parts distribution Business Class M2 Workshop Manual, Supplement 18, September 2010 130/1