TwinFlow Fire Pump 90.00 Valve Removal, Disassembly, Assembly, and Installation Pilot Valve WARNING Park the vehicle on a level surface. Shut down the engine. Set the parking brake and chock the front and rear tires. Use a spring compressor to remove the pilot valve spring. The spring is under compression, and could become uncompressed, which could result in personal injury. 1. Drain the fire pump. 2. Rotate the adjustment handwheel counter- clockwise to remove the spring tension. 6.4 Turn the adjustment handwheel clockwise to unscrew the adjustment shaft from the adjustment nut. From the handwheel end, remove the adjustment shaft from the spring housing. 3.
Remove the capscrew and nut that attach the adjustment handwheel to the adjustment shaft. Then, remove the handwheel. 6.5 Remove both springs, the adjustment nut, and diaphragm clamp as an assembly from the spring housing, then separate them. CAUTION Identify and mark the line connections on the control body before removing. Improper connec- tion of lines may result in the failure of the pilot valve, which could cause damage to the fire pump. 7. Clean all the pilot valve components. Inspect and lubricate with grease the threads on the adjust- ment shaft. 8. Assemble the pilot valve. 4. Remove the pump discharge pressure line and the relief valve line from the control body of the pilot valve.
WARNING 5. While holding the pilot valve, remove the four 1/4–20 x 5/8 machine screws that attach the valve and cover plate to the Pump Operator’s Panel, and separate the valve, plate, and the relief valve setting indicator (if equipped with PMD) from the panel. Use a spring compressor to install the pilot valve spring. The spring is under compression, and could become uncompressed, which could result in personal injury. CAUTION 6. Disassemble the pilot valve. 6.1 Remove the four 5/16–18 x 1 Allen-head capscrews that secure the control body to the rear of the spring housing. Then, re- move the control body.
Always remove the pilot valve discharge pres- sure inlet screen, which is located in the top of the discharge side of the pump. Clean or replace, as necessary. Failure to do so could render the pilot valve inoperative. CAUTION 8.1 Combine both springs, the adjustment nut, and the diaphragm clamp as an assembly, then install the assembly in the spring housing. Align the adjustment nut with the slot in the spring housing and the indicator plate on the PMD. Do not use pliers to unscrew the control valve from the diaphragm clamp. Damage to the con- trol valve will render the pilot valve inoperative. 6.2 Unscrew the control valve from the dia- phragm clamp.
Remove the diaphragm washer and the diaphragm. 8.2 Slide the adjustment shaft into the spring housing from the handwheel end. Turn the adjustment handwheel counterclockwise in order to screw the adjustment shaft into the adjustment nut until it bottoms in the diaphragm clamp. Do not put the springs under tension. 6.3 Remove the retaining ring, the seal and the bearing. Business Class M2 Workshop Manual, Supplement 8, September 2005 150/1