Freightliner — Freightliner Business Class M2 Workshop Manual

TwinFlow Fire Pump 90.00 Valve Removal, Disassembly, Assembly, and Installation TPM Dump Valve 20. Install two 7/16–14 x 1-3/4 capscrews finger-tight (to keep the relief valve cover aligned with the valve body). 1. Drain the pump. 2. Disconnect the indicator light switch. 21. Install the valve spring over the relief valve stem. Then apply pressure to the valve spring to com- press the spring. 3. Disconnect the line to the sensing valve. 4. Remove one 7/16–14 x 2 sensing valve mount- ing capscrew. 22. Install the spring washer and the retaining ring. 5. Remove the four 7/16–14 x 1-3/4 capscrews that retain the relief valve assembly to the atmo- sphere dump. 23.

Remove the two 7/16–14 x 1-3/4 capscrews that were installed to keep the relief valve cover aligned with the valve body. Place the indicator switch assembly into position on the relief valve cover. Apply Loctite ® 242 to the four capscrews, install, and tighten 53 lbf·ft (72 N·m). 6. Remove the four 7/16–14 x 1-1/2 relief valve mounting capscrews to remove the relief valve from the pump body. 24. Apply Loctite ® 242 to the four 7/16–14 x 1-1/2 capscrews to install the new gasket and the relief valve on the pump surface. 7. Remove the relief valve assembly. 8. Remove the four 7/16–14 x 1-3/4 capscrews that retain the relief valve cover to the relief valve body. 25.

Apply Loctite ® 242 to the four 7/16–14 x 1-1/2 capscrews, then install the new gasket and relief valve assembly on the atmosphere dump. Tighten 53 lbf·ft (72 N·m). 9. Remove the indicator light switch assembly. 10. Apply a small amount of pressure to the relief valve spring, and remove the spring retaining ring and washer. Carefully release the pressure held on the spring and remove it. 26. Apply Loctite ® 242 to the 7/16–14 x 2 capscrew, install the sensing valve and tighten the cap- screws 40 lbf·ft (54 N·m). Make sure the arrow points upward. 11. Remove the relief valve cover. 27. Connect the indicator light switch. 12. Remove the piston retaining ring. 28.

Connect the line to the sensing valve. 13. Remove the relief valve from the opposite end, sliding the relief valve stem out of the piston. 29. Fill the pump, then test the valve for proper op- eration and leaks. 14. Reaching through the center hole of the piston, gently pull the piston from the indicator switch end of the relief valve body. Check Valves (two-stage only) 15. Before assembling and installing the valve, clean and inspect all components of the relief valve assembly. 1. Drain the pump. NOTE: There are two check valves (one on each side) in the suction side on the front of the two-stage pump body. The following procedure is used for both check valves. 16.

Clean all sealing gasket surfaces and install new O-rings and gaskets. 2. Remove the four 1/2–13 x 1-1/4 capscrews from the check valve cover on the front side of the pump body. 17. Install the relief valve in the relief valve body. 18. Slide the piston into the relief valve body while at the same time sliding the piston onto the relief valve stem. Then install the piston retaining ring. 3. Remove the check valve. 19. Install the new gasket, then install the cover on the relief valve body. 4. Clean the gasket surfaces, and inspect the check valve pivots and pivot sockets. 5. Install the check valve. Business Class M2 Workshop Manual, Supplement 8, September 2005 150/8