PowerFlow Fire Pump 90.01 Impeller and Clearance Ring Removal and Installation Removal NOTE: When removing clearance rings be care- ful not to damage the clearance ring seating areas in both the suction head and volute hous- ing. WARNING Many of the components on the fire pump are heavy and awkward to handle. Always use the proper support equipment during removal and assembly of the fire pump. Failure to do so could result in an assembly falling which could result in personal injury or property damage. 11. Clean the seating areas for the clearance rings. Installation NOTE:
Freezing the clearance rings prior to in- stallation will greatly enhance installation and reduce the chances of damaging the clearance rings. For a cross-sectional view of the pump, see Fig. 1 . 1. Park the vehicle on a level surface. Shut down the engine. Set the parking brake and chock the front and rear tires. WARNING 2. Drain the water from the pump. The clearance ring is soft brass. Therefore, driv- ing the clearance ring into place with a solid ob- ject will result in a damaged and distorted clear- ance ring that will damage the impeller. NOTE: When installing the clearance rings, be careful to install them square with the clearance ring seat. 3.
Disconnect the intake extension pipes by remov- ing the bolts in both victaulic couplings, separat- ing the halves of the victaulic couplings, then sliding the sealing donuts on the extension tubes. 4. Disconnect the gearbox cooler line from the suc- tion head and the gearbox cooler. 1. Using a soft hammer, tap the clearance ring into place. Be sure the clearance ring seats fully and is square with the clearance ring seat. 5. Remove the intake Y-adapter by removing the eight 3/8– 24 nuts that secure it to the suction head. See Fig. 2 . 2. Clean the impeller shaft. 6. Remove the suction head housing by removing the twelve 3/8 x 24 nuts. Carefully remove the suction head. 3.
Carefully side the impeller on the impeller shaft until it bottoms in the inner clearance ring. 7. Remove the stainless steel cotter pin from the nut that secures the impeller on the impeller shaft. Remove the nut and impeller shaft washer. See Fig. 3 . 4. Install the impeller shaft washer (bevel side out). 5. Install the impeller shaft nut. While tightening the impeller shaft nut, align the cotter pin hole. Tighten it to 50 lbf·ft (68 N·m). IMPORTANT: You must use a stainless steel cotter pin to prevent electrolysis of fastening components, resulting in damage to pump com- ponents. 8. Grasp the impeller and slide it off the impeller shaft.
If the impeller is tight on the impeller shaft, install two bolts in the jack bolt holes, tighten the bolts evenly, and push the impeller off of the im- peller shaft. 9. To remove the front clearance ring (located in the suction head) block the suction head up on two blocks of wood. Then using a small ball peen hammer and small diamond chisel, drive the clearance ring out. See Fig. 4 . 6. Install a new stainless steel cotter pin. 7. Clean the suction head, then install new seals, after lubricating the seals with petroleum jelly to ease installation. 10.
To remove the rear clearance ring (located in the volute housing), use the same small ball peen hammer and small diamond chisel and drive the clearance ring out. See Fig. 5 . 8. Install the suction head, being careful not to damage the seals. Apply Loctite ® 242 to all studs, then install the twelve 3/8–24 nuts. Tighten them to 30 lbf·ft (41 N·m). Business Class M2 Workshop Manual, Supplement 8, September 2005 120/1