PowerFlow Fire Pump 90.01 Impeller and Clearance Ring Removal and Installation 4 2 3 1 07/13/2001 f190038 1. Mechanical Seal 2. Rear Clearance Ring 3. Impeller Shaft 4. Volute Housing Fig. 5, Volute Housing (impeller removed) 10. Install the intake Y-adapter, being careful not to damage the seal. Apply Loctite 242 to the eight 3/8–24 nuts. Install and tighten them to 30 lbf·ft (41 N·m). 11. Slide the extension tubes in until they meet the intake Y-adapter. Slide the sealing donuts on the intake Y-adapter until they are evenly spaced on both the extension tubes and the intake Y-adapter. 12. Install both halves of the victaulic coupling around the sealing donut.
Install and tighten the clamping bolts. Repeat the procedure for the other side. NOTE: Impeller and/or clearance ring replace- ment will necessitate a complete pump service test as detailed in NFPA 1911, Standard for Ser- vice Tests of Fire Pump Systems on Fire Appa- ratus. 13. Fill the pump with water, run it, and inspect it for leaks. 14. Remove the chocks. Business Class M2 Workshop Manual, Supplement 8, September 2005 120/4