Freightliner — Freightliner Business Class M2 Workshop Manual

Paint, Dupont 98.00 Topcoating General Guidelines Mixing This subject provides instructions for applying a top- coat of DuPont ® enamel to full panels or the entire cab. For spot repairs or touch-ups, see Subject 120 . 1. Stir the Imron 5000 enamel thoroughly. 2. Mix three parts Imron 5000 enamel with one part of DuPont 193 S or 194 S activator. No further reduction is necessary for application. CAUTION NOTE: The pot life of the mixture is about 2 to 4 hours at 70°F (21°C), unless an accelerator is added. Only experienced, qualified persons using proper equipment should attempt repainting or touch-up painting.

Incorrect application of chemicals or paint could damage the surface or impair the fin- ish. 3. If faster curing time is desired, add DuPont 389 S fast-dry accelerator. Add up to 2 ounces (60 mL) to 1 gallon (3.8 L) of mixed material. Do not mix additives with the finish coats unless they are specified by the finish-coat manufacturer. See Specifications, 400 for a summary of the products used in this procedure. 4. Mix thoroughly and strain. NOTE: The viscosity of the mixture is about 10 to 19 seconds in a no. 3 Zahn cup, depending on the color. Adding reducer could affect the color match on some metallics. Do not apply if the paint temperature is less than 70°F (21°C).

Use warm water or paint heaters to heat the paint to an optimum temperature of 85 to 95°F (29 to 35°C). The material, substrate or ambient temperature should be above 50°F (10°C) and below 110°F (43°C). Application 1. Set the air pressure at the spray gun to 60 to 65 psi (410 to 450 kPa). For pressure feed systems, set the fluid delivery at 12 to 16 ounces (350 to 470 mL) per minute. Before applying any topcoat: 1. Prepare the surface for topcoating. See Sub- ject 100 for instructions. 2. Apply the topcoating. 2. Clean all cracks and surfaces with dry com- pressed air. 2.1 Hold the spray gun about 10 to 12 inches (25 to 30 cm) from the surface. 3.

Using a tack cloth, wipe all surfaces to be painted. 2.2 Using a cross-coat technique, spray one medium-wet coat in a north-to-south di- rection. Imron 5000 Topcoating 2.3 Allow 5 to 10 minutes drying time be- tween each application. Do not sand. Imron 5000 is a single-stage, low VOC, high-solids polyurethane enamel. It provides a durable, high- gloss surface with good chemical resistance. It re- quires the addition of an activator. 2.4 Apply a second medium-wet coat in an east-to-west direction. 2.5 A third medium-wet coat may be needed for good coverage of some colors. WARNING 3. To air dry, allow 2 to 4 hours with accelerator 389 S, and 6 to 8 hours without the accelerator.

Wear a positive-pressure, supplied-air, vapor and particulate respirator, approved by NIOSH or MSHA (TC-19C) when mixing or spraying paint products, and until the work area has been ex- hausted of all vapor and spray mist. Breathing paint fumes can cause serious personal injury. To force dry, wait 15 minutes following the appli- cation of the final coat, then dry for 30 minutes at 140 to 180°F (60 to 82°C). 4. To prevent tape marking, remove all masking tape and paper immediately after the final coat is applied. Avoid contacting the freshly painted sur- face with masking paper. Business Class M2 Workshop Manual, Supplement 6, March 2004 110/1