Freightliner — Freightliner Business Class M2 Workshop Manual

Paint, DuPont 98.00 Spot Repair 5. Wet sand the area being repaired with 320-grit or finer sandpaper, or a 3M Scotch-Brite ® or similar non-iron abrasive pad. Feather the edge. 10.1 Stir primer thoroughly. 10.2 Mix two parts Corlar epoxy primer with one part DuPont 826 S activator. 6. Remove the sanding dust. Use the same solvent and wipe-on, wipe-off method used earlier to clean the area. 10.3 Reduce three parts of this mixture with one part DuPont 3602 S lacquer thinner (viscosity reading is 18 to 22 seconds in a no. 2 Zahn cup). Stir thoroughly. 7. Mask all areas that will not be painted. 8. Clean all cracks and surfaces with dry com- pressed air.

10.4 Wait 1 to 2 hours from time of mixing be- fore using. This provides time for complete chemical induction. 9. Using a tack cloth, wipe all surfaces to be painted. 10.5 Set the air pressure at the spray gun to 45 psi (310 kPa). For pressure feed systems, set the fluid delivery at 12 to 16 ounces (350 to 470 mL) per minute. WARNING Wear a positive-pressure, supplied-air, vapor and particulate respirator, approved by NIOSH or MSHA (TC-19C) when mixing or spraying paint products, and until the work area has been ex- hausted of all vapor and spray mist. Breathing paint fumes can cause serious personal injury. 10.6 Hold the spray gun about 10 to 12 inches (25 to 30 cm) from the surface.

10.7 Spray one wet coat to give a dry film thickness of 0.7 to 1.0 mil (18 to 25 µm). 10.8 Clean the equipment immediately after use with DuPont 3602 S lacquer thinner. 10. Prime all bare metal and feathered areas with DuPont primer. See Fig. 1 . 10.9 Air dry 2 to 4 hours or force dry 20 min- utes. Steel and aluminum—use Corlar 824 S epoxy primer. Fiberglass—use Corlar 825 S epoxy primer. 11. Wet sand the primer with 400-grit or finer sand- paper. Feather the edge into the surrounding area. 2 3 4 5 12. If the original paint was Imron 6000, hand-rub the area around the spot repair with a medium grade compound to ensure a seamless finish. A A 1 13. Remove the sanding dust.

Use the same solvent and wipe-on, wipe-off method used earlier to clean the area. 14. Wipe the repair area with a tack cloth. 15. If the finish is old, apply one coat of DuPont 222 S adhesion promoter over the entire repair area. 11/11/99 B f980001a NOTE: Scale exaggerated for clarity. The number of layers depends on the specific application. A. Existing Paint B. Panel Material (substrate) 1. Primer 2. First Color Topcoat 3. Second Color Topcoat 4. Third Color Topcoat 5. Clear Coat 15.1 Set the air pressure to 35 psi (240 kPa) at the spray gun. 15.2 Flash for 5 to 10 minutes at 70°F (21°C) before topcoating. Fig.

1, Spot Repair Cross-Section Business Class M2 Workshop Manual, Supplement 7, March 2005 120/2