F. At high speed (If the pilot pressure is higher than 20 kg/cm 2 ) Figure 8 If pilot pressure is supplied from port A (If the pressure is higher than 20 kg/cm ), the valve (163) is pushed to the right bv the spring (166) force, the pressure oil from the supply port B goes through valve (163) into the chamber C. So the piston (161) is fixed because the swash plate (103) is pushed to the plate b of the spindle. At this time, it rotates at high speed because the slope of the swash plate (103) becomes minimum and the piston’s displacement volume becomes minimized (c: 20 kg/cm 2 2 ). S0707365 Page 10 Travel Motor (With Gearbox) (A6V160HD)