Komatsu — 20.6.4 SUPPLEMENTAL COOLANT ADDITIVES

MAINTENANCE Maintain a nominal SCA concentration of 1.0 unit per 3.8 per 3.8 US gal) indicates an under-concentrated coolant solution. More than 2.0 units per 3.8 ) indicates an over-concentrated coolant solution. To check the SCA concentration level, use coolant test kit, CC-2626. Instructions are included with the test kit. Cooling System Test Kit The following cooling system test kit may be purchased from your Komatsu America International Company distributor. This Fleetguard coolant test kit, part number CC-2626 is used to ® check the concentration of coolant additives in the cooling system. 1. Test strip bottles 2. Solution #1 bottle 3. Small plastic container 4. Large plastic cup 5.

Syringe WA380-3MC 3-16 SCA Unit Concentration Guide Number of Solution A Drops to Cause Color Change Coolant Condition Action Required 0 - 10 Drops Extremely under-concentrated - less than 0.4 SCA units per 3.8 (1 US gal) Initially charge the system to a minimum of 1.0 SCA unit per 3.8 11 - 16 Drops Marginally under-concentrated - 0.4 to 0.8 SCA units per 3.8 1 US gal) Add SCA liquid units to maintain 1.0 SCA unit per 3.8 minimum or change the DCA 4 coolant filter. 17 - 25 Drops Acceptable - 0.85 to 1.3 SCA units per 3.8 None. 26 - 35 Drops Highly acceptable - 1.35 to 2.0 SCA units per 3.8 None.

36 - 55 Drops Marginally over-concentrated - 2.1 to 3.3 SCA units per 3.8 S gal) Review maintenance practice. Over 55 Drops Extremely over-concentrated Drain 50% of the coolant and replace with water antifreeze mixture. Retest the system for correct SCA unit concentration.