Komatsu — 24.2.1 CLEAN OR REPLACE AIR CLEANER ELEMENT

MAINTENANCE 24.2 WHEN REQUIRED 24.2.1 CLEAN OR REPLACE AIR CLEANER ELEMENT WARNING Never clean or replace the air cleaner element while the engine is running. When using pressurized air to clean the element, wear safety glasses or goggles to protect the eyes. Checking If the air cleaner clogging caution lamp (1) on the maintenance monitor flashes, clean the air cleaner element. Cleaning or Replacing Outer Element 1. Remove the wing nut (2) and cover (3), and remove the outer element. 2. Clean the inside of the air cleaner body. 3. Direct dry, compressed air, less than 7 kg/cm (100 psi), to 2 the element from the inside along its folds.

Then direct it from the outside along its folds and again from the inside. 1) Remove one seal from the outer element whenever the outer element has been cleaned. 2) Replace the outer element which has been cleaned six times repeatedly or used throughout a year. Replace the inner element at the same time. 3) If the dust indicator display is red immediately after the outer element has been cleaned, replace both the inner and outer elements, especially if the outer element has not been cleaned six times. 4) Check the inner element mounting nuts for looseness and, if necessary, retighten them. Replace the seal washer (5) or wing nut (4) with new parts, if they are broken. NOTE:

After cleaning and drying the element, shine a light through it. If any small holes or thin cracks are found, then replace the element. When cleaning the element, do not hit it or beat it against anything. Do not use an element that has any damaged folds, gaskets, or seals. 5) After cleaning the element, reinstall it. WA380-3MC 3-26