Komatsu — 24.2.11 LUBRICATE WORK EQUIPMENT CONTROL VALVE LINKAGE (2 PLACES)

MAINTENANCE 24.2.9 CLEAN THE AIR CONDITIONER CONDENSER WARNING Do not wash the condenser with a steam cleaner. Other- wise, the condenser will get hot and could break down If there is mud or dust on the air conditioner condenser, clean it with water. When washing with a high pressure machine, apply the water from a reasonable distance. If the water pressure is too high it could deform the fins. Washing Method 1. Open the top cover (1) at the hood front side. 2. Remove bolts (2) at the condenser upper portion. 3. Push condenser backward on pin (3) at the condenser lower portion.

4 Clean condenser with water to the upper portion 24.2.10 CHECK WINDOW WASHING FLUID, ADD FLUID Check the washing fluid level in washer tank (1). When the fluid is low, add automotive window washing fluid. To prevent the nozzle from clogging, be careful not to let dust get into the fluid. 24.2.11 LUBRICATE WORK EQUIPMENT CONTROL VALVE LINKAGE (2 PLACES) If the work equipment control lever is stiff or does not move smoothly, apply grease. 1. Using a grease pump, pump in grease through the grease fittings shown by the arrows. 2. After greasing, wipe any old grease that was pushed out. WA380-3MC 3-34