MAINTENANCE 19. Check that the hydraulic oil is at the standard level. For details, see 24.5 EVERY 100 HOURS SERVICE on page 3- 41. 21. Check to be sure that there are no leaks of oil from the filter cover mount. 24.9.3 REPLACE HYDRAULIC TANK BREATHER ELEMENT WARNING The oil is hot if the machine has just been operated. Wait for the oil to cool down before changing it. When removing the oil filler cap turn it slowly to release the internal pressure, then remove it carefully. 1. Remove the cap of the oil filler A . 2. Remove the snap ring on the breather (1). Remove the breather cap. Replace the filter element with a new part. Install the cap and snap ring. 3.
Tighten the cap of oil filler A . REMARKS It is possible to replace the element with the breather installed in the tank. However, if the breather is removed, do not wrap the taper thread of the breather with seal tape when assembling again, and be careful not to over tighten. 24.9.4 CHANGE AXLE OIL WARNING The oil is hot if the machine has just been operated. Wait for the oil to cool down before changing it. Oil catch container . . . . . . . . . . . . . Min. 190 1. Set a container to catch the oil under drain plug A . Remove front and rear oil filler plugs (1), then remove drain plug A to drain the oil. 2. After draining the oil, clean all the plugs.
Add axle oil through the plug hole (1) to the specified level. For details of the oil to use and refill capacity, see 20 FUEL, COOLANT AND LUBRICANTS ACCORDING TO AMBIENT TEMPERATURE on page 3-9. To be sure that the oil is at the specified level, see 24.2 WHEN REQUIRED on page 3-26. REMARKS For operations where the brake is used frequently, change the axle oil at shorter intervals. WA380-3MC 3-65