OPTIONS, ATTACHMENTS 29.4 PRECAUTIONS WHEN HANDLING ACCUMU- LATOR WARNING The accumulator is charged with high pressure nitrogen gas, which is extremely dangerous, so read the following items and be careful to handle the accumulator properly. If any problem or failure occurs with the accumulator, contact your distributor immediately. The gas must be charged into the accumulator only by a qualified person from your distributor or by a person licensed to handle high pressure gas. Do not bring any flame or heat close to the accumulator when it is charged with gas. Do not make any hole in; or weld anything to, the accumula- tor.
Always release the gas before disposing of the accumulator or disassembling it for maintenance. Use the air bleed valve to release the gas. Every 2000 hours or once a year, have your distributor check the gas pressure. WA380-3MC 5-9