Komatsu — 12.1.2 CHECK BEFORE STARTING

OPERATION DRAIN THE WATER FROM THE FUEL-WATER SEPARATOR 1. With the engine shut-off, open the drain valve (1). 2. Turn the valve counterclockwise about 1-1/2 to 2 turns until draining occurs. Drain the filter sump of water until clear fuel is visible. 3. Do not over tighten the valve. Over tightening can damage the threads. 4. Turn the valve clockwise about 1-1/2 to 2 turns to close the drain valve. 5. Even if a filter/water separator is installed be sure to check the fuel tank to remove water and sediment in the fuel. WA380-3MC 2-41