Deutz — 4.1 CONFIGURATION

SERDIA PARAMETERS 20-30 MK 3 TTG Parameter Unit Min. Max. typ Wert Description Page 34: CAN: (7915)PDU IdentPart Diagnosis Telegr. Active errors 0 65535 65226 EMR status Diglnputs 0 65535 0 EMR status DigOutputs 0 65535 0 Engine temperature 0 65535 65262 engine fluid level/pressure 0 65535 65263 Inlet/Exhaust conditions 0 65535 65270 engine configuration 0 65535 0 Number of errors 0 65535 65230 Passive errors 0 65535 65227 Error Environment Data 0 65535 65229 Engine hours 0 65535 65253 Page 35: CAN: (7930)PDU IdentPart Config. Telegr. EMR: Controller Config. 0 65535 0 EMR:AnalogInput1 Config. 0 65535 0 EMR:AnalogInput2 Config. 0 65535 0 EMR:PWM-Input Config. 0 65535 0 EMR:PWM-Output Config.

0 65535 0 EMR:Dig.Output Config. 0 65535 0 Page 36: CAN: (7938)PDU IdentPart Meas.Values Telegr. Fuel economy 0 65535 65266 EMR measured values 0 65535 0 Page 37: CAN: (7960)Fault codes of rel. fault messages Setpoint generator 1 0 65535 91 Setpoint generator 2 0 65535 201 Boost pressure sensor 0 65535 102 Coolant temperature sensor 0 65535 110 Oil pressure sensor 0 65535 100 Electronics temperature 0 65535 171 EngSpeedSensorl EngRun 0 65535 190 EngSpeedSensor2 EngRun 0 65535 190 RackTravelSensor not vibr. 0 65535 200 Oversp. only during shutd 0 65535 190 Actuator deviation excessive 0 65535 209 Coolant Temp.high(alarm) 0 65535 110 Coolant Temp.

high (shutdown) 0 65535 110 Oil pressure low (alarm) 0 65535 100 Oil pressure low (shutdown) 0 65535 100 PWM Input 2 0 65535 204 PWM Input 1 0 65535 205 Fault data set 0 65535 206 Fault hardware parameters 0 65535 210 Fault CAN 0 65535 203 Fault CAN, voltage too low 0 65535 207 Fault shutdown solenoid 0 65535 208 Fault EDC AutoRegulation 0 65535 202