ALL ROUND TESTER 1. MONITOR 1.MONITOR This menu is used to show the status of input signals for each function. Press to exit this menu. E 1.1 LIFT Status....: Status of lift system Values displayed: LOCK lift locked STOP lift inactive CTRL lift in control condition (e.g. when ploughing) TO UP lift being raised SAFE lift in safety condition Min Pos. Max: Lift position Three columns are displayed: Min: setting selected with the minimum height potentio- meter (values from 0 to max setting). Pos'n: indicates current position of the lift (values from 0 to 100). Max.: setting selected with the maximum height poten- tiometer (values between 0 and 100). Lh Draft Rh : Draft response, right and left.
Three columns are displayed: Lh: signal (in volts) generated by the left side draft sensor. Draft: the value computed as a percentage of the draft generated through the lift. With the tractor stationary and no implement, draft must be 50% approx. Rh: signal (in volts) generated by the right side draft sensor. 20-125 M O N I T O R M E N U = = = = = = = = = = = = = = = = 1 - L I F T 2 - C O N S O L E 3 - A S M 4 - P O W E R 5 - S E N S O R S = = = = = = = = = = = = = = = = [ E ] E x i t L I F T = = = = = = = = = = = = = = = = S t a t u s . . . X X X X X X M i n P o s i t . M a x X % X . X % X % L h d r a f t R h X . X X X . X % X . X X W h e e l s l i p R e f :
X X X X X X % R a d a r K m h X . X W h e e l s K m h X . X M o d e -> X X X X X E V u p X X X E V d w X X X P w m X X X X X X m A [ E ] E x i t