Komatsu — MAINTENANCE INTERVAL FOR HYDRAULIC BREAKER

. MAINTENANCE MAINTENANCE SCHEDULE 4 - 16 MAINTENANCE INTERVAL FOR HYDRAULIC BREAKER For machine equippe d with a hydraulic breaker, the hydraulic oil deteriorates faster than for normal bucket d igging operations, s o set the maintenance intervals as follows Replace hy draulic fi lter element On a new machine, replace the element after the f irst 100 to 150 hours, the n carry ou t fu rther replacemen of element according to the table on t he right. Change oil in hydraulic tan