STRUCTURE, FUNCTION, & MAINTENANCE STANDARD TRAVEL MOTOR OPERATION OF MOTOR 1) Motor swash plate angle at maximum SJP08742 OR 08893 The solenoid valve is deactivated, so the pilot pres- sure oil from the main pump does not flow to port P . For this reason, regulator valve (9) is pushed to the right in the direction of the arrow by spring (10). Because of this, it pushes check valve (22), and the main pressure oil from the control valve going to end cover (8) is shut off by regulator valve (9).
Fulcrum a of rocker cam (4) is eccentric to point of force b of the combined force of the propulsion force of cylinder (6), so the combined force of the piston propulsion force acts as a moment to angle rocker cam (4) in the direction of the maximum swash plate angle. At the same time, the pressurized oil at regulator pis- ton (15) passes through orifice c in regulator valve (9) and is drained to the motor case. As a result, rocker cam (4) moves in the maximum swash plate angle direction, the motor capacity becomes maximum. 10-104 PC210/240-7K