Komatsu — SERVICE PPC VALVE

SERVICE PPC VALVE STRUCTURE, FUNCTION, & MAINTENANCE STANDARD When the pressure at port a becomes higher, spool (1) is pushed back by the force acting on the end of the spool, and fine control portion Y closes. As a result, spool (1) moves up and down to bal- ance the force at port a and the force at metering spring (2). Therefore, metering spring (2) is compressed in proportion to the amount the control lever is moved. The spring force becomes larger, so the pressure at port a also increases in proportion to the amount the control lever is operated.

In this way, the control valve spool moves to a position where the pressure of port A (the same as the pressure at port a ) is balanced with the force of the return spring of the control valve spool. PC210/240-7K 10-131