Komatsu — BOOM HYDRAULIC DRIFT PREVENTION VALVE

STRUCTURE, FUNCTION, & MAINTENANCE STANDARDBOOM HYDRAULIC DRIFT PREVENTION VALVE Function This valve prevents the oil in the boom cylinder bot- tom from leaking through spool (1) and the boom from lowering under its weight while the boom lever is not operated. Operation 1. When boom lever is in "RAISE" position If the boom lever is set in the "RAISE" position, the pressure of the main hydraulic oil is applied toward the left to area "A" of the ring formed by the differ- ence between outside diameter d1 of puppet (5) and seat diameter d2 (= Area of d1 - Area of d2). At this time, if this pressure is higher than the force of spring (4), puppet (5) moves to the left.

By this opera- tion, the main hydraulic oil from the control valve flows through the open part of puppet (5) to the boom cylinder bottom. 2. When boom lever is in neutral If the control lever is returned to the neutral position while the boom is raised, the oil in puppet (5) which has flowed through orifice "a" is sealed by pilot piston (2). The main hydraulic oil is shut off from the holding pressure on the boom cylinder bottom side. At this time, the holding pressure on the boom cylin- der bottom side is applied toward the right to area "A" of the ring formed by the difference between outside diameter d1 of puppet (5) and seat diameter d2 (= Area of d1 - Area of d2).

The total of this pressure and the force of spring (4) closes puppet (5) to shut off the main hydraulic oil from the holding pressure on the boom cylinder bottom. Accordingly, the boom is held. 3. When boom lever is in "LOWER" position If the boom lever is set in the "LOWER" position, pilot spool (2) is pushed by the pilot pressure from the PPC valve and the hydraulic oil in chamber "b" in the puppet is drained through orifice "c". The oil on the boom bottom side flows from orifice "a" through chamber "b" and orifice "c" to the drain hole, and the oil pressure in chamber "b" lowers.

If the pressure in chamber "b" lowers below the pres- sure at port B, puppet (4) opens and the hydraulic oil from port B flows through port A to the control valve. PC210/240-7K 10-137