Komatsu — LIFT CHECK VALVE

STRUCTURE, FUNCTION, & MAINTENANCE STANDARD LIFT CHECK VALVE LIFT CHECK VALVE Function This valve applies back pressure to the drain circuit to prevent generation of negative pressure on the hydrau- lic devices for the work equipment (motors, cylinders, etc.) Operation 1. While engine is stopped Any oil is not supplied from the pump to the self- pressure reducing valve and valve (1) is pressed by only the force of spring (2) toward the right and drain circuit "a" of the control valve is connected through orifice "b" of valve (1) to port T. 2.

While engine is running Output pressure PR of the self-pressure reducing valve is applied through the control valve to spring chamber "c" of the back pressure valve. Output pressure PR applied to spring chamber "c" is applied to the left end of valve (1) (area of d) to push valve (1) to the right. At this time, pressure PA of drain circuit "a" of the control valve is applied to the right end of valve (1) (area of d1) to push valve (1) to the left. Valve (1) is balanced so that the back pressure PA will be as follows. PA = {(Area of d) x PR + Force of spring (2)} / (Area of d1) PC210/240-7K 10-141