STRUCTURE, FUNCTION, & MAINTENANCE STANDARD ATTACHMENT CIRCUIT SELECTOR VALVE Function When a breaker is installed, the return oil from the breaker does not pass through the main valve, but returns directly to the hydraulic tank. When other attachments (crusher, etc.) are installed, the attachment and the main valve are interconnected. Operation 1. When attachment other than breaker is installed Spool (1) is pushed fully to the left by the force of spring (2), ATT port and port V are interconnected, and ATT port and port T are shut off, so the attach- ment and main valve are interconnected. 08901 2.
When breaker is installed When the pilot pressure from the attachment circuit selector solenoid valve overcomes the force of spring (2), the spool (1) moves fully to the right. ATT port and port V are shut off and ATT port and port T are interconnected, so the oil returning from the breaker does not pass through the main valve, but passes through port T and returns directly to the hydraulic tank. 08902 PC210/240-7K 10-143